ASYST Features by Version
What ASYST 3, 3.5, 4.0 and 4.1 can each do: capabilities, working fluids and platforms
What do all ASYST versions have in common?
Every ASYST version is built on the same RELAP5/SCDAPSIM physics core. The real differences between versions are the working fluids, which analysis modules come built in, the display, and the platform.
- 17 hydraulic component types
- 24 control component types
- SCDAP severe accident components
- NCSU 3DKIN 3-D nodal kinetics
- Wilks-based uncertainty analysis
- COUPLE lower head and debris models
ASYST 3
Based on RELAP5/SCDAPSIM RS3.4. Light water and heavy water, 32-bit Windows and Linux, an OpenGL nodalization display and the SciGraph plotter. Uncertainty analysis and hydraulic loads are build options.
ASYST 3.5
The same physics as ASYST 3, including all 11 noncondensable gases and the Kurchatov/WWER material options 70–73.
ASYST 4.0
Moves to modular Fortran 90 source and adds built-in liquid metals and molten salts. Uncertainty analysis and hydraulic loads are always included, and simulator DLL variants are added. O2, CO2 and CO noncondensables and the Kurchatov options are dropped.
ASYST 4.1
Adds lead and solar salt with automatic liquid-metal heat transfer, new lead options 70 and 71, and Kurchatov MATPRO as option 72. 64-bit Windows and Linux, a live 3-D display and a code-signed installer.
ASYST capabilities, version by version
| Feature | ASYST 3 | ASYST 3.5 | ASYST 4.0 | ASYST 4.1 |
|---|---|---|---|---|
| Hydraulics | ||||
| 17 hydraulic component types: pipe, branch, pump, valve, accumulator, separator, jet mixer, turbine, ECC mixer, pressurizer and others | Yes | Yes | Yes | Yes |
| Level tracking; horizontal and vertical stratification | Yes | Yes | Yes | Yes |
| Boron transport (Godunov scheme, option 23) | Yes | Yes | Yes | Yes |
| Critical flow: default, Henry-Fauske, modified Henry-Fauske (option 53) | Yes | Yes | Yes | Yes |
| Noncondensable gas species (card 110) | 11 | 11 | 8 | 8 |
| Fluids | ||||
| Working fluids available (see the full list) | 2 | 2 | 11 | 13 |
| Liquid-metal heat transfer correlations | No | No | Option 63 | Automatic |
| Heat transfer | ||||
| Reflood, 2-D conduction, radiation enclosures, gap conductance | Yes | Yes | Yes | Yes |
| CHF: AECL-UO 1986 table, PG-CHF, Kutateladze, SRL, ORNL | Yes | Yes | Yes | Yes |
| Materials | ||||
| Kurchatov / WWER MATPRO options | Options 70–73 | Options 70–73 | No | Option 72 |
| Kinetics | ||||
| Point kinetics with reactivity feedback | Yes | Yes | Yes | Yes |
| NCSU 3DKIN 3-D nodal kinetics (hexagonal geometry, adjoint, depletion, pin power) | Build option | Build option | Build option | Build option |
| Severe accident | ||||
| SCDAP components: fuel rod, control rod, shroud, BWR blade/box, ATR, CORA | Yes | Yes | Yes | Yes |
| COUPLE lower head, debris, molten pool, fission products, B4C chemistry | Yes | Yes | Yes | Yes |
| Analysis | ||||
Uncertainty analysis (Wilks method, uncsetup / uncpost) |
Build option | Build option | Included | Included |
Hydraulic loads (LOADC, frcsum control) |
Build option | Build option | Included | Included |
| Output | ||||
| Restart-plot, strip, CSV strip and XMGR export | Yes | Yes | Yes | Yes |
| Coupling | ||||
| DLL build for coupling to other codes | Yes | Yes | Yes | Yes |
| Simulator DLL variants | No | No | Yes | Yes |
Part of every standard build of that version.
In the code, and compiled into builds that enable it. Ask us when ordering.
Not available in that version.
Which working fluids does each ASYST version support?
Only ASYST 4.0 and 4.1 can run liquid-metal or molten-salt coolants. ASYST 3 and 3.5 are water and heavy-water codes.
ASYST 3 and 3.5
Light water and heavy water only. Both versions accept 12 other fluid names inherited from RELAP5, but each of those needs an external property file that is not supplied, so they can't be run. Heat transfer uses the standard water package; there are no liquid-metal correlations.
ASYST 4.0
Adds built-in sodium, lead-bismuth eutectic (LBE), lithium-lead, three fluoride molten salts and two light-water table variants. No external property files are needed. Liquid-metal heat transfer correlations are used only when option 63 is set on card 1.
ASYST 4.1
Everything in 4.0, plus pure lead (Pb) and solar salt. Liquid-metal and solar-salt heat transfer correlations are selected automatically from the fluid type, with no option needed.
ASYST fluid support, version by version
The input name goes on the system card (cards 120–129), for example
120 100010000 0.0 pbbi primary.
| Fluid | Input name | ASYST 3 | ASYST 3.5 | ASYST 4.0 | ASYST 4.1 |
|---|---|---|---|---|---|
| Water | |||||
| Light water | h2o |
Usable | Usable | Usable | Usable |
| Heavy water | d2o |
Usable | Usable | Usable | Usable |
| Light water, NIST-based tables | h2os |
No | No | Usable | Usable |
| Light water, alternate tables | h2om |
No | No | Usable | Usable |
| Liquid metal | |||||
| Sodium | na |
Name only | Name only | Usable | Usable |
| Lead-bismuth eutectic (LBE) | pbbi |
No | No | Usable | Usable |
| Lead | pb |
No | No | No | Usable |
| Lithium-lead | lipb |
Name only | Name only | Usable | Usable |
| Molten salt | |||||
| FLiBe (LiF-BeF2) | flibe |
No | No | Usable | Usable |
| FLiNaK (LiF-NaF-KF) | flinak |
No | No | Usable | Usable |
| KF-ZrF4 | kfzrf4 |
No | No | Usable | Usable |
| Solar salt (nitrate) | ssalt |
No | No | No | Usable |
| Other | |||||
| User placeholder (FLiBe correlations) | newfluid |
No | No | Usable | Usable |
| Legacy RELAP5 | |||||
| NaK | nak |
Name only | Name only | Disabled | Disabled |
| Lithium | li |
Name only | Name only | Disabled | Disabled |
| Potassium | k |
Name only | Name only | Disabled | Removed |
| Hydrogen | h2 |
Name only | Name only | Disabled | Disabled |
| Helium | he |
Name only | Name only | Disabled | Disabled |
| Nitrogen | n2 |
Name only | Name only | Disabled | Disabled |
| Ammonia | nh3 |
Name only | Name only | Disabled | Disabled |
| Light water, P-U tables | h2on |
Name only | Name only | Disabled | Disabled |
| Glycerol | glycerol |
Name only | Name only | Disabled | Disabled |
| Blood | blood |
Name only | Name only | Disabled | Disabled |
The fluid's properties are built into the code or ship with it.
The name is accepted, but no property file is supplied, so the fluid can't be run.
The code rejects the name and resets the fluid to water.
The fluid is not in that version's fluid list.
Helium, nitrogen, argon and other gases remain available in every version as noncondensable gases on card 110. They just can't be the working fluid.
Liquid-metal and molten-salt models in ASYST 4.1
The ASYST 4.1 models are intended for single-phase system thermal-hydraulic analysis, not coolant boiling or severe accidents.
| Fluid | Property basis | Bundle heat transfer | Pipe heat transfer |
|---|---|---|---|
| Sodium | Fink and Leibowitz | Mikityuk | Lyon |
| Lead | Pure-lead correlations (UPB) | Mikityuk (option 71) or Kazimi-Carelli/Ushakov | Seban-Shimazaki, or Kutateladze (option 70) |
| LBE | OECD/NEA 2015 LBE Handbook | Ushakov, or Kazimi-Carelli (option 59) | Subbotin (Pe ≤ 4000) |
| Lithium-lead | Built-in correlations | Ushakov | Subbotin (Pe ≤ 4000), Lyon above |
| Solar salt | Built-in correlations | Bundle correlation | Sellars (laminar) |
| FLiBe, FLiNaK, KF-ZrF4 | Built-in correlations | Standard package | Standard package |
What are the current limits of the liquid-metal models?
- No coolant boiling The liquid-metal heat transfer routines set wall vapor generation to zero. Vapor-side properties are developed only for LBE.
- No liquid-metal severe accidents The SCDAP severe accident models apply to water fluids only.
- No fast-reactor extras There are no wire-wrap friction models and no metallic-fuel properties.
- Validation in progress Sample input decks exist for LBE (ADS loops), lead and FLiBe. Comparison against experimental data for the liquid-metal models has not yet been published.
Which platforms and tools does each ASYST version use?
The big platform step is ASYST 4.1, the first version to ship 64-bit with a code-signed installer and the new live 3-D display.
| Item | ASYST 3 | ASYST 3.5 | ASYST 4.0 | ASYST 4.1 |
|---|---|---|---|---|
| Windows | 32-bit | 32-bit | 32-bit | 64-bit |
| Linux | Yes | Yes | Yes | Yes |
| Compiler | Intel ifort | Intel ifort | Intel ifort | Intel ifx |
| Built-in display | OpenGL nodalization display | OpenGL nodalization display | OpenGL nodalization display | Live 3-D display (Vulkan) |
| Launcher / UI | Java launcher, SACTHA | SACTHA | Java launcher, Python UI | SACTHA (sactha.exe) |
Live 3-D display in ASYST 4.1
Watch a run as it happens: hydraulic noding, heat-structure temperature maps, the COUPLE mesh, SCDAP core damage, oxidation and hydrogen, and in-run graphs. The display is for viewing; input decks are still edited as text.
Simulator coupling
Every version builds as a DLL for coupling to other codes. ASYST 4.0 adds simulator DLL variants, and ASYST 4.1 adds an entry point that hands the display, volume and junction data to an external simulator host.
Not sure which ASYST version fits your reactor?
Tell us your coolant and the transients you need to analyse, and we will recommend the right version.